The basic principles of the method for optimizing the calculation of volume-flow parameters of surface runoff (rain and melt) treatment facilities for the I–III category enterprises according to their negative impact on the environment are presented. The use of the method provides for reducing the design capacity of the treatment facilities by 3–5 times with a corresponding reduction in capital and operating costs while fully complying with the requirements of the current design rules as evidenced by the expert examination of design documentations.