Kurdiumov V. R., Timofeev K. L., Kraiukhin S. A.

Specific features of using reverse osmosis for mine water treatment

Summary

The possibility of using reverse osmosis for treatment of mine water from dead copper-nickel pits was studied. The composition of mine water was, mg/dm3: Mn 0,6–1; Fe 0,01–0,1; Ni 0,8–1,5; Cu 0,3–0,5; Zn 0,05–0,25; Co 0,02–0,07; Na 35–50; Ca 125–150;
Mg 35–45; SO4 100–200; Cl 65–75; Al 0,02–0,05; Si 9–11; Se 0,1–0,2; As < 0,005; Te < 0,005; Pb < 0,005; Hg < 0,00005; salt content 750–850; total hardness 9.5–11.5 °dGH; рН 7–7.5. The studies were carried out in a pilot plant with a capacity of 1 m3/h with original mine water. The plant included ultrafiltration and reverse osmosis modules. The permeate yield varied in the range of 50–75% of the original water volume. The method of chemical mine water demanganation and de-ironing at the primary treatment stage was tested. The quality of effluent (permeate) fully conforms to the drinking water requirements. The operating conditions of the pilot plant are described; the chemical unit consumption is presented. The specific features of using reverse osmosis technology for mine water treatment are described. The basic performance indicators of the reverse osmosis unit in terms of the equivalent amount of 1 m3/h at
the effluent output of 75% of the inflow are presented. The method of concentrate utilization is described providing its yield is reduced to 5% which makes it possible to extract valuable admixtures (non-ferrous metals).

Key words

, , , , , , ,

 

№10-2|2010

POTABLE WATER SUPPLY

bbk 000000

UDC 628.136:725.74.002.56.004.1

Medkov B. K.

Features of Operation of Control and Measuring Equipment in Water with Higher Carbonate Hardness

Summary

Reasons for the failure of control and measuring equipment determining the free residual chlorine in a swimming pool’s water are considered. In process of the equipment operation deposits on a measuring electrode of a running-water cell and corrosion of a counter electrode are observed. The inspection of the swimming pool’s water treatment system, chemical analysis of deposits on the measuring electrode and analysis of the pool’s water allow to suppose that this water composition favors the calcium carbonate deposition on the surfaces of pipelines and equipment. The assessment of water stability shows that the index of saturation with calcium carbonate is sufficiently high. Results of the experimental study of stabilizing treatment of water for the purpose of reducing the index of saturation with calcium carbonate are presented. Dozes of reagents selected optimally favor the normal operation of equipment.

Key words

, , , ,

 