Seliukov Aleksandr, Semenov Mikhail, Baikova Ida

In-process tests of river water conditioning for domestic and drinking water supply in the city of Kurgan

Summary

The experience of using ozonation of river water on a laboratory and pilot scale is considered. The water of the Tobol River is hard and mineralized with an average color value of 24 degrees, a manganese concentration in the winter period of more than 0.8 mg/dm3. After determining the operational doses of the chemicals (polyaluminum chloride coagulant, Praestol 650TR flocculant), test ozonation was carried out followed by the chemical treatment in a laboratory flocculator. To achieve the standard for manganese concentration in river water of 0.1 mg/dm3, high doses of ozone were required – from 35 mg/dm3. Alkalinization of the initial water to pH 9 provided for reducing the ozone dose to 23 mg/dm3. A decrease in color to 15 degrees occurred at ozone doses of 6–7 mg/dm3. River water purification at a pilot plant with a capacity of 50 l/h was carried out according to the complete process flow scheme (ozonation, treatment with coagulant and flocculant, sedimentation, filtration in a sand filter, filtration in a carbon filter, desalination-softening by reverse osmosis). The coagulant dose was 5 mg/dm3, and that of the flocculant – 0.3 mg/dm3. In the steady run of the pilot plant at an ozone dose of 25 mg/dm3, the following quality indicators of the sand filter filtrate were achieved: color 5–7 degrees; manganese 0.05–0.15 mg/dm3; total iron 0.02–0.03 mg/dm3; aluminum 0.05–0.08 mg/dm3; permanganate index 3–4 mg/dm3. Based on the estimate indicators of the Tobol River water composition related to the manganese concentration in water of 0.8 mg/dm3, the theoretic dose of ozone is ≈ 8 mg/dm3, the design dose of ozone can be assumed as 10 mg/dm3 (g/m3).

Key words

, , , ,

The further text is accessible on a paid subscription.
For authorisation enter the login/password.
Or subscribe

REFERENCES

  1. Draginskii V. L., Alekseeva L. P., Samoilovich V. G. Ozonirovanie v protsessakh ochistki vody [Ozonation in water treatment processes. Moscow, DeLi Print Publ., 2007, 395 p.].
  2. [Potential of enhanced oxidation. The use of ozone in water treatment: theoretic and practical aspects]. Voda Magazine, 2013, no. 3 (67), pp. 26–30. (In Russian).
  3. Tekhnicheskii spravochnik po obrabotke vody (Degrémont) [Technical handbook on water treatment. V. 1. Saint-Petersburg, Novyi Zhurnal Publ., 2007, 1696 p.].
  4. Metodiki provedeniia tekhnologicheskikh izyskanii i modelirovaniia protsessov ochistki vody na vodoprovodnykh stantsiiakh [Methods for conducting technological research and modeling of water purification processes at water treatment plants. Moscow, NII KVOV OJSC, Vodkommuntekh LLC Publ., 2001, 57 p.].

Журнал ВСТ включен в новый перечень ВАК

Шлафман В. В. Проектирование под заданную ценность, или достижимая эффективность технических решений – что это?

Banner Kofman 1